HOME STUDIO: Cool DIY Plan – How To Air Condition Your Voice Over Home Studio Recording Booth, by Greg Thomas
The following contains graphic pictures of exposed duct work that may
not be suitable for those who are sensitive to interior design or
practice feng shui. This project also comes with the potential for a low
spousal approval rating. Check with your significant other before
proceeding.
conditions have caught most of the country by surprise.
For those of us in Texas, though, it’s business as usual.
temperatures above the century mark, sometimes for a week or more, are
common all over the state from June to August.
If you’ve never experienced a Texas summer, it’s hard to imagine what
it’s like living with that kind of heat on a daily basis.
experience) that an isolation booth can quickly turn into a little sweat
box, especially in the summer. The computer fan and dryer hose that
typically come with a booth just can’t keep up with torrid summertime
heat.
only their underwear because their booth was so hot. Even if the booth starts out at a moderate temperature, after you’re
in there for 20 or 30 minutes, your body heat alone will cause the
temperature to rise significantly.
room-temperature air into a heavily insulated booth in the summertime,
it’s a losing battle. Your body heat can’t get out fast enough, and the
isolation booth turns into a padded dry sauna.
the air conditioner was blowing cold air onto my balding head.
air must have kicked my brain cells into action, because it got me to
thinking …
pits, sweat-stained scripts, and repeatedly opening the door of the
booth to try to cool off? There was only one way to find out.
Build something (I didn’t know what just yet,) and see if it worked.
the booth by getting more air into it, I enlarged the ventilation hole
from 4 inches to 6 inches, and pushed room air into the booth through a
Panasonic FV-15VQ5 WhisperCeiling 150 CFM Exhaust Bath Fan that I’d
bought to replace the ineffective computer fan.
(Be careful opening this stuff. It tends to come out of the wrapper like one of those spring-loaded snakes in a can.)
into the ceiling vent and get the cold air to the fan. After a
long-distance call to a good buddy who used to run his own air
conditioning company, I knew I had a plan.
…
plenum (that’s a fancy HVAC word for box) that fits inside the duct box
where the air comes out.
ventilate the room, and another hole to connect to the existing Panasonic fan.
which is why I was able to pull this off so cheaply. I only had to buy a
little bit of plywood, some clamps, a titanium drill bit to cut through
the metal duct box in the ceiling, a hole saw kit, paint, glue,
anchors, and some round adapters. (You’ll find a complete list, with
prices, at the end of this article.)
down 2’feet from the 9 foot ceiling.
deliberately a very tight fit, but it’s also attached to the ceiling
with expansion bolts just to be sure it doesn’t fall out.
(If you decide to build a plenum, remember the old rule: measure twice, cut once. Or in my case, measure 3 or 4 times.)
to mount a grille, and cut a 4″ hole in the side for the 4″ to 6″ round adapter that connects it to the Quietflex.
- The cold air comes out of the side of the plenum.
- A 3 foot section of
Quietflex carries the cold air from the plenum to the Panasonic fan,
and - Another section of Quietflex carries the cold air from the fan to
the booth.
we’re not at home.
the booth was typically about 82°F.
But that was before I got in there and started voicing scripts.
After I’d been in the booth for 15 or 20 minutes, I was sweating away
because the temperature was up to 88°F.
20 minutes.
Just from my own body heat.
76°F booth, and the temperature does not rise during a session. Instead
of working in an 88°F booth, I now work in a 76°F booth.
And if I set the house thermostat on 75°F, I can get the booth down to 70°F.
order to force enough air into the booth to keep it cool, but I don’t.
The Panasonic fan pulls enough cold air into the booth without closing
the grille, so both the room and the booth stay cool.
before, the noise floor hasn’t changed. My VU meter still bounces around
between -54db to -57db when normalized to -3db. Not Hollywood recording
studio quiet, but quiet enough to keep my clients happy.
proper baffle box instead of connecting the duct work directly to the
booth.
(Not even the psycho barking dog across the back fence.) So I’m not sure
how much improvement I would see in the noise floor by building one.
didn’t work, I wouldn’t be out an arm and a leg, and if it did work, I’d
be cool.
And for a guy who never was one of the cool kids growing up, being cool is a big deal.
- 6″ to 4″ round reducer to connect the plenum to the Quietflex, $7.57
- 8″ to 6″ round reducer to connect the Quietflex to the Panasonic fan, $8.67
- 10″ x 10″ to 8″ ceiling register box to connect the Panasonic fan to the 8″ to 6″ round reducer, $12.86
- Three 6″ hose clamps, $5.94
- 3/16″ titanium drill bit, $3.48
- Air intake/exhaust hood with screen, 6″ (take the screen out), $27.48
- Two pieces of 15/32″ common pine sanded plywood, $12.54
- A tube of Elmer’s WoodGlue Max to glue the plenum together, $2.68
- Package of 2.5″ corner braces to attach the plenum to the ceiling, $2.98
- 10″ x 6″ 3-way air register (because the old one was rusty), $7.63
- Can of black spray paint to make the shiny metal match the Flexduct, $5.88
- Hole saw set to cut a round hole in the plenum. Found it on sale for $9.99
- Masonry anchors to secure the plenum to the ceiling, $2.28
that I already had the Quietflex duct, the Panasonic fan, and a Variac
left over from my previous attempt to cool off the booth.
able to keep costs down and tie your current booth into an air
conditioning duct using something similar to the design I created.
Panasonic fan I’m using has been discontinued and replaced with a three
speed model. I’m assuming it’s a better unit, but can’t guarantee that.
You’ll still need a Variac transformer to slow it down, though.
are sources for the Panasonic fan, the Quietflex duct, and the Variac
transformer:
- Panasonic FV-1115VQ1 Whisperceiling DC Fan, $235.99
- Quietflex
6″ QAS Flex Duct. Contact company for pricing. - Variac SC-3M transformer,
$74.95
cord to connect the fan to the wall socket. Cut the socket off of the
extension cord and hard wire the cord to the fan.
at full speed, I slow the fan down to half speed with a Variac
transformer. If you decide to slow your fan down, do not use a standard
light dimmer to slow it down. A light dimmer won’t keep the electricity
at 60 Hz, and it will eventually burn out the fan motor. A Variac
prevents this.
Thomas, aka the Deep, Warm Voice, lives in San Antonio, TX with his
wife and an extraordinary standard poodle. Greg is a recovering
broadcaster who has been voicing scripts to inform, sell, and persuade
audiences in the U.S., Canada, Europe, China, and the Middle East for over
25 years. He has been recording VO from his professional home studio
for more than 10 years. In
his life before freelance voice over, Greg owned and managed a 100,000
watt radio station that he built from the ground up when he was 32. He
won 13 local Addy awards while he managed the station. His
VO clients include Verizon, Brawny Paper Towels, University of Notre
Dame, Irwin Vice Grip, Wounded Warrior Project, New York Red Bulls
Soccer, CSX Transportation, DuPont Pioneer, and Brugal Rum. When he’s
not behind the mic or editing, he drives his wife, kids, and grandkids
crazy with his Dad jokes.